Polwax Config 21CFR
21 CFR PART 11 CONTROLSNOT SIGNED IN
Polwax › Dashboard
Software
Polwax Config 21CFR
Validated-system framework
Logger Data
0
Imported records
Audit Events
1
Time-stamped events
Integrity
Ready
Hash-chain check
Compliance Control StatusCONTROLLED
Unique user identification

Individual user identity for controlled actions.

Authority checks

Role-based access to configuration and approval.

Audit trail

Time-stamped creation and modification history.

Electronic signature

Two-factor signing workflow with meaning.

Record protection

Read-only source data and controlled report records.

Validation evidence

IQ/OQ/PQ evidence register and version control.

System Information
SoftwarePolwax Config 21CFR
Version2.4.0
ModeLocal / Controlled
Current UserAdministrator
Time ZoneAsia/Kolkata
Validation StatusValidation required before regulated use
Important: This HTML application implements a Part 11-oriented control framework and demonstration workflows. It is not, by itself, a regulatory certification. Production use requires documented system validation, risk assessment, SOPs, security controls, backup/restore testing, infrastructure qualification and approval by the responsible quality unit.
Polwax › Datalogger Configuration
Datalogger ConfigurationControlled Configuration
Channel ConfigurationConfigure measurement labels, units and limits
ChannelParameterUnitLow LimitHigh LimitEnabled
Polwax › Import .CUB Data
Controlled Data ImportOriginal data preserved
Source record rule: Imported source data is treated as read-only. The application creates a controlled working copy for report generation and records the import event in the audit trail.
Source File
—
Original filename
Records
0
Valid timestamped records
First Record
—
Logger-local time
Last Record
—
Logger-local time
Imported Observation Data0 records
Polwax › Report Generator
Report Records
0
Records in selected range
Report Type
Controlled
21 CFR workflow
Source Integrity
—
Import hash
Approval
Draft
Electronic signature required
Report DefinitionDraft until signed
Report Channel SelectionOnly selected channels will appear in the report, graph and observation table.
0 channels selected≤ 10 channels: A4 Portrait   |   > 10 channels: A4 Landscape
The report filter compares the original logger-local timestamp fields exactly as recorded by the logger. No browser timezone conversion is applied.
Polwax › Report Repository
Controlled Report RepositoryNamed Records
Controlled record rule: Reports are retained with their report number, title, source integrity, selected channels, date/time range, status and electronic approval history. Draft reports are view-only. Download/export is enabled only after Administrator approval.
Polwax › Audit Trail
Computer-Generated Audit TrailHash Chain Enabled
Audit trail principle: Significant creation, modification, approval and access events are recorded with user, timestamp, action and reason. In a production system, the audit repository must be protected from user modification and disabling.
Polwax › Electronic Signatures
Signature Policy
Signature ComponentsUser ID + Password + action meaning
Signature MeaningReview / Approval / Configuration Change
Signature BindingBound to controlled record ID
Re-signingRequired after material change
AccountabilityIndividual user credentials
Sign Controlled Action
Polwax › Users & Roles
User & Role AdministrationAdministrator only
Password / Access Policy
Unique User ID

No shared accounts permitted for regulated actions.

Password Complexity

Minimum length, complexity and expiration policy.

Account Lockout

Lock after repeated unsuccessful authentication attempts.

Session Timeout

Automatic logout after inactivity.

Polwax › Validation
Computerized System ValidationNot yet qualified
Validation is required: FDA guidance describes validation as a control for computerized systems. The application provides a validation evidence register, but execution, approval and release remain the responsibility of the regulated organization.
URS Approved

User Requirements Specification approved.

Risk Assessment

Data integrity and patient/product quality risks assessed.

IQ Completed

Installation Qualification executed.

OQ Completed

Operational Qualification executed.

PQ Completed

Performance Qualification executed.

SOP Approved

Operating, security, backup and audit review SOPs approved.

Validation Evidence
Polwax › System & Security
Security Controls
Access Control

Role-based permissions.

Authority Checks

Controlled actions restricted by role.

Operational Checks

Input and workflow checks.

Device Checks

Device identity and source verification.

Record Retention

Retention period and archive policy.

Backup / Restore

Controlled backup and restoration testing.

Encryption

Recommended for production storage and transport.

Time Reference

Explicit timezone and timestamp reference.

System Time & Record Integrity
Current Time—
TimezoneAsia/Kolkata
Audit Hash—
Source DataRead-only after import
Report StatusDraft until electronic approval